A 10A HEMP equipment filter meeting the pci requirements of IEC61000-4-24 pulses for severity levels 1 and 2. Both lines feature individual inductive input to offer both good continuous wave EMC performance and superior transient handling performance even on supplies with low source impedance. The filter includes HEMP and EMC filtering components thus reducing the need for a separate EMC input filter for the equipment. If additional EMC filtering is needed, it can readily be provided at board level. This filter is primarily designed to protect individual items of equipment against the E1 pulse as part of a staged protection system as described earlier in this catalogue.
INSERTION LOSS PERFORMANCE
Asymmetric attenuation shown as measured in 50Ω system, at all loading conditions, in accordance with CISPR-17.
For more details and catalogues please visit MPE’s website or contact Radiotechnika Marketing Sp. z o.o. directly.
MPE’s website:
Commercial HEMP/EMC Equipment Filter Range
Design: Proformat